Steam trap TB51
- SCCV system
- Stainless steel
- Suitable for condensate recovery
- Horizontal installation
- Vertical installation
- Bypass function
- Automatic venting
- Option
– Customized flange
-
Completely closed
The temperature control trap enables adjustable subcooling of the condensate. This maintains a specific condensate level in the trap. The mechanism is 100% leak-proof, which effectively prevents steam loss during operation.
-
Suitable for high pressures, high temperatures and superheated steam.
-
Outstanding durability
The MIYAWAKI SCCV system (Self Closing and Centering Valve) is characterized by a significantly longer service life thanks to the reduced closing forces.
The freely rotating valve always sits optimally in the valve guide, even under the extreme conditions that prevail in high-pressure applications, as it is centered and guided by the condensate flow. This design significantly reduces stress and therefore wear on the valve components. -
Fast commissioning
Discharges the cold condensate and cold air quickly.
Also functions as a deaerator.
-
Energy savings
Controlling the temperature of the discharged condensate ensures significant energy savings.
-
Low operating noise and very low formation of flash steam
Typical applications
Suitable for steam main lines, steam tracing and other similar applications.
Threaded socket / Welding socket
Nominal width | Dimensions (mm) | Weight | |||
---|---|---|---|---|---|
L | H1 | H2 | W | (kg) | |
1/2″ | 130 | 155 | 25 | 100 | 5,7 |
3/4″ | |||||
1″ |
Flange
Nominal width | Flange standards | Dimensions (mm) | Weight | ||||
---|---|---|---|---|---|---|---|
Type | L | H1 | H2 | W | (kg) | ||
1/2″ | JIS (RF) | 20K | 155 | 25 | 100 | 7,3 | |
30K | 8,4 | ||||||
40K | 8,7 | ||||||
63K | 220 | 9,6 | |||||
ASME/JPI (RF) | 150lb | 200 | 6,7 | ||||
300lb | 7,2 | ||||||
600lb | 7,3 | ||||||
900lb | 220 | 9,6 | |||||
3/4″ | JIS (RF) | 20K | 210 | 7,7 | |||
30K | 8,9 | ||||||
40K | 9,2 | ||||||
63K | 230 | 11,1 | |||||
ASME/JPI (RF) | 150lb | 210 | 7,7 | ||||
300lb | 8,2 | ||||||
600lb | 8,5 | ||||||
900lb | 230 | 10,9 | |||||
1″ | JIS (RF) | 20K | 240 | 9,2 | |||
30K | 10,1 | ||||||
40K | 10,5 | ||||||
63K | 12,1 | ||||||
ASME/JPI (RF) | 150lb | 8,3 | |||||
300lb | 9,4 | ||||||
600lb | 9,6 | ||||||
900lb | 13,3 | ||||||
DN15 | DIN PN63/PN100 | 210 | 155 | 25 | 100 | 9,4 | |
DN20 | 230 | 11,4 | |||||
DN25 | 230 | 12,1 |
* Customized dimensions on request.
* Please contact MIYAWAKI if you require further information.
Model | Connection | Max. Operating pressure (bar) | Max. Differential pressure (bar) | Max. Operating temperature (℃) | Setting range (℃) | Default setting (℃) | Housing material | |
---|---|---|---|---|---|---|---|---|
Type | Nominal size | |||||||
TB51-45 | Threaded socket Rc, NPT |
1/2″ | 45 | 45 | 425 | 100 – 220 | 180 (at 21 bar) |
Forged steel A105 |
3/4″ | ||||||||
1″ | ||||||||
TB51-65 | 1/2″ | 65 | 65 | 100 – 240 | 220 (at 44 bar) |
|||
3/4″ | ||||||||
1″ | ||||||||
TB51F-45 | Flange RF |
1/2″ | 45 | 45 | 100 – 220 | 180 (at 21 bar) |
||
3/4″ | ||||||||
1″ | ||||||||
TB51F-65 | 1/2″ | 65 | 65 | 100 – 240 | 220 (at 44 bar) |
|||
3/4″ | ||||||||
1″ | ||||||||
TB51W-45 | Welding socket | 1/2″ | 45 | 45 | 100 – 220 | 180 (at 21 bar) |
||
3/4″ | ||||||||
1″ | ||||||||
TB51W-65 | 1/2″ | 65 | 65 | 100 – 240 | 220 (at 44 bar) |
|||
3/4″ | ||||||||
1″ |
* The factory-set standard temperature can be changed. Please enter the operating pressure and set temperature.
* Information on adjusting the setpoint temperature can be found in the installation instructions.
● ⊿t is the difference between the temperature of a temperature control trap when the valve is first opened and the temperature of the condensate. The temperature difference (⊿t) at the first flow of air is large and indicates that the flow rate will also increase.
* Curve 1 shows the maximum capacity of the trap when discharging cold condensate.
** Curve 2 shows the maximum capacity of the trap when discharging hot condensate at a temperature of 10 °C below the setpoint temperature of the trap.